|
♦Drive Function
Drive Function Operating Instructions
Subdivision set by SW5-SW8 four DIP switches to set the number of micro-step breakdown of the drive , which has 15 stalls micro-step . When users set the micro-step , you should stop the drive to run. See detailed breakdown set the table .
The output current is set by SW1-SW3 three DIP switches to set the driver output current , the output current total of eight files.
Automatic half current function the user can set the drive through SW4 automatic half current function. Quiescent current is set to half off said dynamic current , on said quiescent current and dynamic current is the same . General applications should SW4 is set to off, so that the motor and the drive to reduce fever , increased reliability . After a burst of about 0.4 seconds to stop automatically reduced to about half of the current (60 % of the actual value ) , reduced to 36% of the theoretical heat .
Signal Interface PUL + and PUL- control pulse signal positive terminal and a negative terminal , pulse falling edge ; HIGH 4 ~ 5V, low level 0 ~ 0.5V. For reliable response to the pulse signal , the pulse width should be greater than 1.2μs. Such as when using +12 V or +24 V 1K or 2K series resistor required ;
DIR + and DIR- signal for the direction of the positive terminal and a negative terminal ; high / low signal , in order to ensure reliable motor commutation , the direction of the signal should be at least 5μs pulse signal is created. The initial direction of the wiring of the motor on the motor , interchange any phase windings ( eg A +, A- exchange ) can change the initial operation of the motor driving , the DIR- HIGH 4 ~ 5V, the low level 0 ~ 0.5V. Such as when using +12 V or +24 V 1K or 2K series resistor required .
ENA + and ENA- enable signal to the positive terminal and a negative terminal . This input signal is used to enable or disable . ENA + pick +5 V, ENA- connected low ( or internal optocoupler conduction ) , the drive current of the motor will cut off all phases of the motor is in a free state, then step pulse is not responding. When not required for this function, you can enable signal end vacant .
FAU + and FAU- alarm output signal is a positive terminal and a negative terminal .
Positive and negative terminals B + and B- B -phase stepping motor connected windings ; positive and negative ends of the motor interfaces connected to A + and A- A phase stepper motor windings . When the A, B two-phase windings any negative exchange when a group , can reverse the motor direction .
Power Interface AC1, AC2 using single-phase AC power supply, operating voltage range recommendations : AC 85-265V.
There are two red and green indicator lights drive . Where the green light for the power indicator on the drive power when the green light ; red fault indicator , when an overvoltage , overcurrent fault , the fault lights lit . After the fault is cleared , the red light is off . When a drive fails , only the power on again and re-enabled in order to clear the fault.
Communication port US2272A achieve set number of users subdivision and change the setting pulse input mode , half- time and other parameters of the flow through the RS232 interface to communicate with the computer , US2272A dedicated communication cable must be used to communicate with the computer , self- wiring can easily result in errors caused by wiring burned communication interface circuit . Drive factory parameters to meet the requirements of most users , dedicated communication cables as an alternative to buy parts for the user , there is a need to change the parameters of the user can contact the drive manufacturer.
Installation instructions for the drive Dimensions : 198 × 86 × 103mm, installation pitch of 185mm. When installed, it should be close to the metal cabinet to facilitate cooling .
Note 1 is higher than the input voltage is lower than AC85V AC265V, the drive will automatically protect ;
2, the input control signal level is 5V, 5V when the need is higher than limiting resistor ;
3 , the falling edge of the input pulse signal is valid ;
4, the cooling fan in the drive when the drive is started when the temperature is over 48 working゜
5 When the drive stops working , the drive temperature exceeds 80 degrees゜, ALM fault indicator lit until the drive temperature
When down to 50 degrees, need to re-power the drive to return to work. Please install the radiator overheating protection ;
6 , overcurrent (short circuit ) ALM fault indicator lights , check the wiring and other electrical short circuit fault , after exclusion
Need to re-power recovery ;
7 , no motor ALM fault indicator light , check the electrical wiring on the need to exclude the power is restored .
♦ current setting
Peak current mean current SW1 SW2 SW3
2.40A 1.70A on on on
3.08A 2.18A off on on
3.77A 2.66A on off on
4.45A 3.15A off off on
5.14A 3.63A on on off
5.83A 4.12A off on off
6.52A 4.61A on off off
7.20A 5.10A off off off
♦ quiescent current settings
SW4 = on the same quiescent current and dynamic current .
SW4 = off half the quiescent current of the dynamic currents ( recommended )
♦ Set subdivision
Pulse / rev SW5 SW6 SW7 SW8
400 off on on on
800 on off on on
1600 off off on on
3200 on on off on
6400 off on off on
12800 on off off on
25600 off off off on
1000 on on on off
2000 off on on off
4000 on off on off
5000 off off on off
8000 on on off off
10000 off on off off
20000 on off off off
25000 off off off off
♦ Dimensions
|