♦ Drive Function
Drive function
Operating Instructions
Set the number of segments
By the SW5-SW8 four DIP switches to set the number of micro-step breakdown of the drive , which has 15 stalls micro-step . Users set the micro-step
When broken down , stop the drive to run. See detailed breakdown set the table .
Output current setting
The SW1-SW3 three DIP switches to set the driver output current , the output current total of eight files.
Automatic half current function
Users can set the drive through SW4 automatic half current function. Quiescent current is set to half off said dynamic current,
on said quiescent current and dynamic current is the same . General applications should SW4 is set to off, so that the motor and drive
Reduce heat , improving reliability . After a burst of about 0.4 seconds to stop automatically reduced to about half of the current ( actual value
60% ) , the theoretical heat to 36 %.
Signal Interface
PUL + and PUL- control pulse signal positive terminal and a negative terminal , the pulse rising edge ; HIGH 4 ~ 5V, low
When 0 ~ 0.5V. For reliable response to the pulse signal , the pulse width should be greater than 1.2μs. If using +12 V or +24 V
1K or 2K takes string resistance ;
DIR + and DIR- signal for the direction of the positive terminal and a negative terminal ; high / low signal , in order to ensure reliable motor commutation, directional radio
No pulse signal should be at least 5μs established. The initial wiring of the motor with the motor running direction is related to any swap
Phase winding (e.g., A +, A- exchange ) can change the initial operation of the motor driving , the DIR- HIGH 4 ~ 5V, LOW
When 0 ~ 0.5V. Such as when using +12 V or +24 V 1K or 2K series resistor required .
ENA + and ENA- enable signal to the positive terminal and a negative terminal . This input signal is used to enable or disable . ENA + pick +5 V, ENA
- Then low ( or internal optocoupler conduction ) , the drive current of the motor will cut off all phases of the motor in a free state ,
At this step pulse is not responding. When not required for this function, you can enable signal end vacant .
Motor Interface
Positive and negative terminals B + and B- phase winding connected to the stepper motor B ; A + and A- negative terminal connected to the A-phase stepper motor winding. When A,
B positive and negative exchange any two-phase windings of a group , can make the reverse motor direction .
Power Interface
AC or DC power supply operating voltage range recommendations : DC36-110VDC, or AC20-AC90V, electricity
Source power greater than 300W.
Indicator
Drive has two red and green lights . Where the green light for the power indicator on the drive power when the green light ; red light is
Fault indicator , when an overvoltage , overcurrent fault , the fault lights lit . After the fault is cleared , the red light is off . When the drive
When a fault occurs , only the power on again and re-enabled in order to clear the fault.
Installation Instructions
The dimensions of the drive : 151 × 97 × 48mm, installation pitch of 143mm. Both horizontal and vertical installation, construction
Meeting with vertical installation. When installed, it should be close to the metal cabinet to facilitate cooling .
♦ current setting
Peak current
Mean current
SW1
SW2
SW3
2.40A
1.70A
on
on
on
3.08A
2.18A
off
on
on
3.77A
2.66A
on
off
on
4.45A
3.15A
off
off
on
5.14A
3.63A
on
on
off
5.83A
4.12A
off
on
off
6.52A
4.61A
on
off
off
7.20A
5.10A
off
off
off
♦ quiescent current settings
SW4 = on the same quiescent current and dynamic current .
SW4 = off half the quiescent current of the dynamic currents ( recommended )
♦ Set subdivision
Pulses / revolution
SW5
SW6
SW7
SW8
400
off
on
on
on
800
on
off
on
on
1600
off
off
on
on
3200
on
on
off
on
6400
off
on
off
on
12800
on
off
off
on
25600
off
off
off
on
1000
on
on
on
off
2000
off
on
on
off
4000
on
off
on
off
5000
off
off
on
off
8000
on
on
off
off
10000
off on off off
20000
on off off off
25000
off off off off
♦ Dimensions
|